Radiation Measurement and Nuclear MedicineHigh-Performance Analytical Equipment
icon_language
icon_share
Share
icon_search
Search

Hidex 300 SL

Hidex 300 SL

The revolutionary Hidex 300 SL

The Hidex 300SL is a revolutionary instrument with compact size, incorporating the most advanced triple-PMT detector technology facilitating: exceptionally high counting efficiency, luminescence free counting mode, and absolute activity counting without external radioactive source using triple-to-double coincidence ratio (TDCR) method.


Device Parmeters

The revolutionary Hidex 300 SL

The Hidex 300SL is a revolutionary instrument with compact size, incorporating the most advanced triple-PMT detector technology facilitating: exceptionally high counting efficiency, luminescence free counting mode, and absolute activity counting without external radioactive source using triple-to-double coincidence ratio (TDCR) method.

The most advanced, compact and user friendly LSC on the market

Compact and transportable

The Hidex 300 SL has a modern and compact design measuring half the size and weight of some of its long standing rivals. It is therefore much easier to install and fit it into smaller, more space conscious laboratories, such as transporting in research vessels or mobile labs.

Technical innovations

Absolute activity counting with TDCR technology

The detector with 3 PMTs enable triple-to-double coincidence ratio counting TDCR, which is an absolute counting method for obtaining counting efficiency of the samples without external or internal standard sources. Unlike external standard methods, TDCR is a universal method applicable for both chemical and color quenching, for aqueous and organic samples and for different cocktails and range of isotopes. TDCR method can be used for counting of typical beta isotopes and also for absolute activity determination of Cherenkov radiation e.g. from 90Y/90Sr. Quench correction by conventional External Standard method is available as optional feature (462-019) for laboratories that prefer to continue measurements with the conventional method.

Luminescence free counting

Hidex 300 SL can be used in triple coincidence mode only, which removes interference from chemiluminescence and reduces the effect of other low energy noise events. Samples with long luminescence decay such as 14C in NaOH can be counted immediately without the need to dark adapt.

Exceptionally high counting efficiency

The Hidex 300 SL utilizes three PMTs aligned at 120° from each other. Optimum detection geometry yields in better detection geometry than conventional double coincidence detector. And the more there is quenching, the greater the advantage of triple coincidence detector

Example: Efficiency for H-3 (in 20 ml vials)


Hidex 300SL

Double Coincidence Counters

Unquenched:

> 70 %

65 %

H-3 in water:

> 35 %

25 %

H-3 in water, high quench:

10%

5 %

Alpha/beta separation

Most advanced alpha beta separation is available as an option on the Hidex 300 SL. It facilitates extremely sensitive detection of alpha isotopes in presence of high beta radiation. Calibration and results validation can be done using convenient and reliable 2D/3D spectrum analysis tool without laborious and isotope specific misclassification run. Separation works even for unknown mixture of alpha and beta isotopes. This reduces the possibility on measurement errors typical for conventional misclassification methods, where calibration is done in often in different conditions and isotopes than found in unknown samples. Typical applications include detection of Rn-222, Ra-226/228, Am-241 and gross alpha/beta.

User friendly software

The Hidex 300 SL is operated using an external PC with Windows 10 or higher based MikroWin 300 SL software, featuring an easy-to-use graphical interface and extensive data reduction capabilities, including quench curve analysis and half-life correction. The software is designed for multiuser environment, enabling unlimited number of methods for different isotopes and easy data export to Excel or other programs. Users can add samples with new methods, and high priority samples while the instrument is counting. MikroWin is also 21 CFR Part 11 compliant.

Technical Specification

Sample capacity, 20mL/7mL

40/96

Counting efficiency H-3/C-14 (%)

70/96

Background H-3 in water (CPM)

12

Dimensions, W/H/D (cm)

52/68/63

Weight (kg)

125

Optional features

525-003 alpha/beta separation

462-019 External Eu-152 std source

425-2003 Cooling

425-016 Low Level Option


Our Advantages

icon_pro_detail_advan_1

Stable performance

Stable performance is a symbol of quality, which can withstand repeated testing and long-term testing, bringing peace of mind and trust to users.

icon_pro_detail_advan_2

Advanced Technology

Advanced technology leads to higher efficiency, better performance, better user experience and lower costs.

icon_pro_detail_advan_3

Functional Excellence

It represents the perfect pursuit of product design and implementation, a perfect combination of quality and innovation, and can bring users a richer and more efficient experience.

icon_pro_detail_advan_4

Strong applicability

It reflects the comprehensiveness and depth of the product design, ensuring that users can obtain a satisfactory experience in different situations.